[Classic Dossier] Element=etClassicDossier International Waterski & Wakeboard Federation 2016 Edition Homologation Dossier - Classic IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM code of competition:18S047 site code: USAS0722 name of competition:Little Mountain Big Dawg Qualifier Date:09/16/2017 09/17/2017 Venue:Little Mountain Farms Organizing Country:USA GPS Location of site: 35.3504.ON,-81.0448.8W Type of competition (International ) Were cash prizes or merchandise awarded (Yes/No) (Yes ) Amount: 3000 Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) Event Round 1 Round 2 Round 3 Round 4 Slalom ( R) ( R) ( R ) ( ) Tricks ( ) ( ) ( ) ( ) Jump ( ) ( ) ( ) ( ) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) (OK) 2. Speed Control (W 10.07) ( ) Manufacturer:Zero Off Software Version:R slalom (OK) tricks ( ) jump ( ) 3. Arrangement for checking skis (W 10.03) (OK) 4. Measure lines and handles (W 10.04) ( ) slalom (OK) jump ( ) handles (OK) 5. Arrangement for checking of skier supplied handles (W 10.06) (OK) 7. Homologation notice posted before start (OK) 8. Automatic timing-jump (NA) 9. Jump distance indication (W 13.11) (NA) 10.Video Jump Distance measurement (W 13.11)( ) Backup - video tape or standard meters ( ) 11.Automatic timing-slalom All Buoys (OK) 12.Position and height of slalom towers (OK) (W 14.05 and W diagram 6) 12a. Slalom Officials: 1 boat judge + 2 central tower with boat video 13.Slalom buoys (W 14.06) (OK) 14.VHS vid/digital slalom endcourse(W 14.17)(OK) 15.Trick course checked (W diagram 3) ( ) 16.Position and height of trick towers ( ) (W 15.11) 16a. 5 Judges ( ) 1 x 3 Judges with video ( ) 2x 3 Judges with video ( ) 17a. Video Tricks Timing ( ) with Additional judge ( ) Chief Judge ( ) 18.VHS video/digital tricks (W15.15) ( ) 19a.Video Tricks Timing system manufacturer ( ) 20.SLALOM COURSE TYPE:Single anchor buoys 21.VHS video/digital jump endcourse(W13.08a)( ) 22.The ramp surface is a flat plane(W13.02f)( ) (no designed in wedge, kicker, bow, etc.) JUMP COURSE JUMP MEASUREMENT SETUP VIDEO JUMP 40m Test buoy 3rd Test buoy Survey x (XXX.XX) y (XXX.XX) Survey x (XXX.XX) y (XXX.XX) Video system x (XXX.XX) y (XXX.XX) Video system x (XXX.XX) y (XXX.XX) 60m Test buoy Survey x (XXX.XX) y (XXX.XX) Video system x (XXX.XX) y (XXX.XX) Manufacturer of Jump Video System : JUMP RAMP Width at top (W 13.02a) X.XX m Width at bottom X.XX m Top edge to 6.4m line left side (W 13.02b,h) X.XX m Top edge to 6.4m line right side (W 13.02b.h) X.XX m Top edge to 6.8m line left side (W 13.02b,h) X.XX m Top edge to 6.8m line right side (W 13.02b.h) X.XX m Length underwater from 6.8m line (W 13.02c) X.XX m Maximum Deviation from plane Diagonal string measurement (W 13.02f) X.X cm Center string measurement (W 13.02f) X.X cm Max deviation point from top of jump (W 13.02f) X.XX m (OK/X) Apron under water (W 13.02g) ( ) Apron full length (W 13.02g) ( ) Sighting line (W 13.02i) ( ) Secure anchoring (W 13.02i) ( ) Apron Angle (W 13.02k) jump height X.XX m (a) length of edge of apron from top corner to water X.XX m (b) ratio of b/a (X.XXX) ( ) minimum 0.883 maximum 0.643 RAMP SETTING Right Side Left Side Setting Height Length Ratio Height Length Ratio 1.50 XXX.X XXX.X XXX.X XXX.X XXX.X XXX.X 1.65 XXX.X XXX.X XXX.X XXX.X XXX.X XXX.X 1.80 XXX.X XXX.X XXX.X XXX.X XXX.X XXX.X NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used (Yes/No) ( ) Protractor reading units (Degrees/Grades) ( ) METER SETUP Distance (T1 - T2/A - B) (XXX.XX meters) Distance (T2 - T3/B - C) (XXX.XX meters) if not a straight line Distance (T1 - T3/A - C) (XXX.XX meters) Inter-meter angles (if not a straight line) T1/A T2/B T3/C Meter T1/A XXXXX 180.0 180.0 Meter T2/B 0.0 XXXXX 180.0 Meter T3/C 0.0 0.0 XXXXX (note shown numbers are examples - fill in with actual numbers) SET UP SIGHTINGS Angle Ramp 15ET T1/A upper XXX.X XXX.X T1/A lower XXX.X XXX.X T2/B upper XXX.X XXX.X T2/B lower XXX.X XXX.X T3/C upper XXX.X XXX.X T3/C lower XXX.X XXX.X Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp X.XX meters inscribed circle diameter at 15ET X.XX meters Jump system survey results (X-Y coordinates) X Y Ramp XXX.XX XXX.XX Table 1/A XXX.XX XXX.XX Table 2/B XXX.XX XXX.XX Table 3/C XXX.XX XXX.XX Buoy 15ET XXX.XX XXX.XX Attach the computer printout file at the end after the Homologation Notice Computer program checked against (OK/X) "Computer Benchmark for Computed Distances" ( ) METER STATIONS Stability and horizontal level ( ) Protractors on same vertical line ( ) Protractor graduations (max 0.2 degrees) ( ) Radius of protractors (min 0.25 m) ( ) Accuracy of sighting arms ( ) END OF HOMOLOGATION FORM It is important to leave the above section in the exact format as it will be processed automatically. The following section is where free form comments are added and attachments are made. HOMOLOGATOR'S REMARKS None Homologator: John Brooks 119 Castleton Dr Mooresville, NC PH 704-664-0471 email: buckeye1nc@windstream.net Chief Judge: John Wilkins Lake Placid, NY PH 518-524-3154 wilkins@centralny.twcbc.com wilkins@northnet.org Scorer: Keith Lindemulder 5720 Carnegie Blvd Charlotte, NC 28211 PH 704-996-8294 This homologation record has been emailed to Bob Corson, bcorson@comcast.net for E&A: email also to Donal Connolly, homologation@splasheye.com HOMOLOGATION NOTICE Tournament Name:Little Mountain Queens Cup Date:09/16/2017 09/17/2017 We recommend to the IWWF Tournament Council the following class of homologation: Event Round 1 Round 2 Round 3 Round 4 Slalom (R ) (R ) ( R ) ( ) Tricks ( ) ( ) ( ) ( ) Jump ( ) ( ) ( ) ( ) Speed Control Manufacturer:Zero Off Software Version:R Mode for tricks (if applicable):Classic Date _________ ________ _______ Time _________ ________ _______ Chief Judge Homologator _John Wilkins___ ___John Brooks__ Note: These recommendations may change during the competition. Remarks: Due to lake configuration, central judges tower, with gate video, end course video and boat , is located at 3 ball and not between 3 & 4 (4&5). If the tower were placed between 3 & 4 bouy, it would be much further from the centerline and the trees would be in the way of the view. The tower floor is in excess of the required guideline. Also due to lake configuration, gate camera tower nearest starting dock, is not as elevated as desired by the rules. The camera does have acceptable magnification to clearly view gates.