International Water Ski Federation 2010 Edition Homologation Dossier - Classic IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM code of competition: 11AUS322 code of site:3040 name of competition:VicState Championships Date:2/4/2011 - 3/4/2011 Venue:Wilsons Road Geelong Organizing Country:Australia Type of competition ( 2 round 3 event ) Were cash prizes or merchandise awarded (Yes/No) (No ) Amount: Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) Event Round 1 Round 2 Round 3 Round 4 Slalom (L ) (L ) ( ) ( ) Tricks (L ) (L ) ( ) ( ) Jump (N ) (N ) ( ) ( ) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) (OK) 2. Speed Control (W 10.07) (OK) Maunfacturer:Zero Off Software Version:Ver.Q slalom (OK) tricks (OK) jump (OK) 3. Arrangement for checking skis (W 10.03) (OK) 4. Measure lines and handles (W 10.04) (OK) slalom (OK) jump (OK) handles (OK) 5. Arrangement for checking of skier supplied handles (W 10.06) (OK) 6. Timing devices (W 11.03) (OK) 7. Homologation notice posted before start (OK) 8. Automatic timing-jump (OK) Optional Timing Method ( ) 9. Jump distance indication (W 13.11) (OK) 10.Video Jump Distance measurement (W 13.11)(OK) Backup - video tape or standard meters (Video) 11.Automatic timing-slalom Dual Segment ( ) All Buoys (OK) 12.Position and height of slalom towers (OK) (W 14.05 and W diagram 6) 12a. Slalom Officials:5 2 on each tower, one in boat. 13.Slalom buoys (W 14.06) (OK) 14.VHS video slalom endcourse (W 14.17) (OK) 15.Trick course checked (W diagram 3) (OK) 16.Position and height of trick towers (NA) (W 15.11) 16a. 5 Judges ( ) 1 x 3 Judges with video ( ) 2x 3 Judges with video (OK) 17.Semi-automatic timing-20sec (W 15.12) (NA) automatic median start (NA) 17a. Video Tricks Timing (NA) with Additional judge ( ) Chief Judge (OK) 18.VHS video tricks (W15.15) (OK) 19a.Video Tricks Timing system manufacturer (IWWF Corson system VTT04v5 ) 20. 2nd Speed Control Display used S/J (OK) SLALOM COURSE TYPE :Cross Line with side anchors to effect adjustment with survey JUMP COURSE Cross line JUMP MEASUREMENT SETUP VIDEO JUMP 40m Test buoy Survey x (NA.XX) y (NA.XX) Video system x (NAX.XX) y (NA.XX) 60m Test buoy Survey x (NA.XX) y (NA.XX) Video system x (NA.XX) y (NA.xx) Manufacturer of Jump Video System :Splash Eye JUMP RAMP Width at top (W 13.02a) X.XX m Width at bottom X.XX m Top edge to 6.4m line left side (W 13.02b,h) X.XX m Top edge to 6.4m line right side (W 13.02b.h) X.XX m Top edge to 6.8m line left side (W 13.02b,h) X.XX m Top edge to 6.8m line right side (W 13.02b.h) X.XX m Length underwater from 6.8m line (W 13.02c) X.XX m Maximum Deviation from plane Diagonal string measurement (W 13.02f) X.X cm Center string measurement (W 13.02f) X.X cm (OK/X) Apron under water (W 13.02g) (OK) Apron full length (W 13.02g) (OK) Sighting line (W 13.02i) (OK) Secure anchoring (W 13.02i) (OK) Apron Angle (W 13.02k) jump height 1.73 m (a) length of edge of apron from top corner to water 2.20 m (b) ratio of b/a (0.786) ( ) minimum 0.883 maximum 0.643 RAMP SETTING Right Side Left Side Setting Height Length Ratio Height Length Ratio 1.50 1.61 6.78 0.237 1.61 6.78 0.237 1.65 1.73 6.78 0.255 1.73 6.78 0.255 1.80 1.83 6.78 0.269 1.83 6.76 0.270 NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used (Yes/No) ( ) Protractor reading units (Degrees/Grades) ( ) METER SETUP Distance (T1 - T2/A - B) (XXX.XX meters) Distance (T2 - T3/B - C) (XXX.XX meters) if not a straight line Distance (T1 - T3/A - C) (XXX.XX meters) Inter-meter angles (if not a straight line) T1/A T2/B T3/C Meter T1/A XXXXX 180.0 180.0 Meter T2/B 0.0 XXXXX 180.0 Meter T3/C 0.0 0.0 XXXXX (note shown numbers are examples - fill in with actual numbers) SET UP SIGHTINGS Angle Ramp 15ET T1/A upper XXX.X XXX.X T1/A lower XXX.X XXX.X T2/B upper XXX.X XXX.X T2/B lower XXX.X XXX.X T3/C upper XXX.X XXX.X T3/C lower XXX.X XXX.X Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp X.XX meters inscribed circle diameter at 15ET X.XX meters Jump system survey results (X-Y coordinates) X Y Ramp XXX.XX XXX.XX Table 1/A XXX.XX XXX.XX Table 2/B XXX.XX XXX.XX Table 3/C XXX.XX XXX.XX Buoy 15ET XXX.XX XXX.XX Attach the computer printout file at the end after the Homologation Notice Computer program checked against (OK/X) "Computer Benchmark for Computed Distances" ( ) METER STATIONS Stability and horizontal level ( ) Protractors on same vertical line ( ) Protractor graduations (max 0.2 degrees) ( ) Radius of protractors (min 0.25 m) ( ) Accuracy of sighting arms ( ) END OF HOMOLOGATION FORM It is important to leave the above section in the exact format as it will be processed automatically. The following section is where free form comments are added and attachments are made. HOMOLOGATOR'S REMARKS Cross Line coarse with close in shore weights used for adjustment for accuracy, set while survey in progress. ie. Moomba Style. Recent survey completed by Bob Beazley. Sighted during Tournament to monitor accuracy OK. Due to errors in setup of grid buoys for SplashEye system, subtraction done to readings to correct errors in calculation. While unable to class as List however, I suggest figures of sufficient accuracy to class as OK for Ratings in Australia. Error correction appeared to be consistent across range of landing area. Only three judges for Tricks with immediate review. Suggest results Ok for list and ratings in Australia. Homologator: (name and address) Tony Cunningham 15 Railway Terrace Kangaroo Flat Vic. 3555 Email: tonygc2010@optusnet.com.au Chief Judge: (name and address) Ron Fergusson Parkdale Victoria Scorer: (name and address) Richard Crisp richardcrisp@bigpond.com.au This homologation record has been emailed to Bob Corson, bcorson@comcast.net for EAME: email also to Marc Raymond, SKIRAYMO@aol.com