[Classic Dossier] Element=etClassicDossier International Water Ski Federation 2009 Edition Homologation Dossier - Classic IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM code of competition:11AUS312 code of site: AUS3035 name of competition:List Assist Date:11/12/10 12/12/10 Venue:Cowra Station Mildura Organizing Country:Australia Type of competition (National ) Were cash prizes or merchandise awarded (Yes/No) (No ) Amount: Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) Event Round 1 Round 2 Round 3 Round 4 Slalom ( L) ( L) ( L) ( ) Tricks ( ) ( ) ( ) ( ) Jump ( L) ( L) ( L) ( ) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) (OK) 2. Speed Control (W 10.07) ( ) Maunfacturer:Zero Off Software Version:Q slalom (OK) OK tricks (NA) NA jump (OK) OK 3. Arrangement for checking skis (W 10.03) (OK) 4. Measure lines and handles (W 10.04) ( ) slalom (OK) OK jump (OK) OK handles (OK) OK 5. Arrangement for checking of skier supplied handles (W 10.06) (OK)OK 6. Timing devices (W 11.03) (OK) 7. Homologation notice posted before start (OK) 8. Automatic timing-jump (OK) Optional Timing Method (OK) 9. Jump distance indication (W 13.11) (OK) 10.Video Jump Distance measurement (W 13.11)(OK) Backup - video tape or standard meters (Meters ) 11.Automatic timing-slalom Dual Segment (OK) All Buoys (OK) 12.Position and height of slalom towers (OK) (W 14.05 and W diagram 6) 12a. Slalom Officials: 1 boat judge + 4 judges, 2 on each side of the lake (W 14.13) 13.Slalom buoys (W 14.06) (OK) 14.VHS video slalom endcourse (W 14.17) (OK) 15.Trick course checked (W diagram 3) (NA) 16.Position and height of trick towers (NA) (W 15.11) 16a. 5 Judges (NA) 1 x 3 Judges with video (NA) 2x 3 Judges with video (NA) 17.Semi-automatic timing-20sec (W 15.12) (NA) automatic median start (NA) 17a. Video Tricks Timing (NA) with Additional judge (NA) Chief Judge ( ) 18.VHS video tricks (W15.15) (NA) 19a.Video Tricks Timing system manufacturer ( ) 20. 2nd Speed Control Display used S/J (NA) SLALOM COURSE TYPE :Single anchor buoys JUMP COURSE JUMP MEASUREMENT SETUP VIDEO JUMP 40m Test buoy Survey x (39.66 ) y (-7.62 ) Video system x (39.69 ) y (-7.76 ) 60m Test buoy Survey x (57.54 ) y (-7.81 ) Video system x (57.61 ) y (-7.95 ) Manufacturer of Jump Video System :Corson JUMP RAMP Width at top (W 13.02a) 4.26 m Width at bottom 4.26 m Top edge to 6.4m line left side (W 13.02b,h) 6.4 m Top edge to 6.4m line right side (W 13.02b.h) 6.4 m Top edge to 6.8m line left side (W 13.02b,h) 6.7 m Top edge to 6.8m line right side (W 13.02b.h) 6.8 m Length underwater from 6.8m line (W 13.02c) .73 m Maximum Deviation from plane Diagonal string measurement (W 13.02f) 2.1 cm Center string measurement (W 13.02f) 1.9 cm (OK/X) Apron under water (W 13.02g) (OK) Apron full length (W 13.02g) (OK) Sighting line (W 13.02i) (OK) Secure anchoring (W 13.02i) (OK) Apron Angle (W 13.02k) jump height 1.65 m (a) length of edge of apron from top corner to water 2.35 m (b) ratio of b/a (0.702) ( ) minimum 0.883 maximum 0.643 RAMP SETTING Right Side Left Side Setting Height Length Ratio Height Length Ratio 1.50 1.60 6.80 0.235 1.61 6.8 0.237 1.65 1.74 6.80 0.256 1.75 6.8 0.257 1.80 1.84 6.79 0.271 1.85 6.79 0.272 NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used (Yes/No) ( ) Protractor reading units (Degrees/Grades) ( ) METER SETUP Distance (T1 - T2/A - B) (XXX.XX meters) Distance (T2 - T3/B - C) (XXX.XX meters) if not a straight line Distance (T1 - T3/A - C) (XXX.XX meters) Inter-meter angles (if not a straight line) T1/A T2/B T3/C Meter T1/A XXXXX 180.0 180.0 Meter T2/B 0.0 XXXXX 180.0 Meter T3/C 0.0 0.0 XXXXX (note shown numbers are examples - fill in with actual numbers) SET UP SIGHTINGS Angle Ramp 15ET T1/A upper XXX.X XXX.X T1/A lower XXX.X XXX.X T2/B upper XXX.X XXX.X T2/B lower XXX.X XXX.X T3/C upper XXX.X XXX.X T3/C lower XXX.X XXX.X Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp X.XX meters inscribed circle diameter at 15ET X.XX meters Jump system survey results (X-Y coordinates) X Y Ramp XXX.XX XXX.XX Table 1/A XXX.XX XXX.XX Table 2/B XXX.XX XXX.XX Table 3/C XXX.XX XXX.XX Buoy 15ET XXX.XX XXX.XX Attach the computer printout file at the end after the Homologation Notice Computer program checked against (OK/X) "Computer Benchmark for Computed Distances" ( ) METER STATIONS Stability and horizontal level ( ) Protractors on same vertical line ( ) Protractor graduations (max 0.2 degrees) ( ) Radius of protractors (min 0.25 m) ( ) Accuracy of sighting arms ( ) END OF HOMOLOGATION FORM It is important to leave the above section in the exact format as it will be processed automatically. The following section is where free form comments are added and attachments are made. HOMOLOGATOR'S REMARKS During the final round of jump, the jump broke loose. All anchor ropes were new prior to the event, as was the jump. An unforeseen sharp edge on the jump had cut through one anchor rope only. The Ramp centre (RCTR) had been marked during the survey (because the jump was new, the RCTR was marked with an individual anchor and noodle). The HEXM was also marked on the shore with star post with PVC pipe over it during the survey. After the jump anchor was severed during the competition, the severed anchor rope was repaired, and pulled taught again. As the other 3 anchor ropes remained undamaged, re-tensioning the one broken anchor rope once more positioned the jump to its previous surveyed position. This was verified by the marked RCTR buoy, and also aligning the HEXM to the mark on the shore. It took under 30mins to rectify the jump. The jump broke loose after the first jump of Callum McMurray, U17B during the final round of jump. Callum was awarded a re-ride for this jump due to the failure. Homologator: Gavin McMillan 6 Reginald St Quarry Hill 3550 Email: Chief Judge: Peter Cornale Riverside Ave Mildura VIC 3500 Scorer: Rebecca McMillan 6 Reginald St Quarry Hill 3550 This homologation record has been emailed to Bob Corson, bcorson@comcast.net for EAME: email also to Marc Raymond, SKIRAYMO@aol.com HOMOLOGATION NOTICE Tournament Name:List Assist Date:11/12/10 12/12/10 We recommend to the IWSF Tournament Council the following class of homologation: Event Round 1 Round 2 Round 3 Round 4 Slalom (L ) (L ) (L ) ( ) Tricks ( ) ( ) ( ) ( ) Jump (L ) (L ) (L ) ( ) Speed Control Manufacturer:Zero Off Software Version:Q Mode for tricks (if applicable):________________________ Date _________ ________ _______ Time _________ ________ _______ Chief Judge Homologator ____________________ ________________ Note: These recommendations may change during the competition. Remarks: Jump 150m buoy and 180m buoy are discoloured due to recent flooding.